You can readily inspect and reduce the product variations of large pipe, hose, and tubes up to 120mm (4.72 inches) in diameter with LaserLinc's TLAser2120 Dual-Axis Micrometer.
The TLAser2120 micrometer can continuously measure product diameters and product position in two planes at right angles to each other. A maximum gauging rate of 8,000 measurements per second enables the TLAser2120 micrometer to precisely check diameter and ovality while also detecting lumps and neck-downs to assure the most thorough quality inspection possible.
Incorporating a mirror-based design, the rugged TLAser2120 Micrometer features a heavy aluminum body with sealed metal covers for lasting performance in harsh industrial environments. An optional air purge mounts easily to the gauge.
The TLAser2120, like all LaserLinc micrometers, is designed to serve only one purpose -- to precisely measure the product's dimensions and route them to a PC. The TLAser2120 micrometer operates with the popular TLAser400 Interface Card and related software to more economically and effectively control product quality by capitalizing on the enormous processing power and flexibility of today's PC.
|
|
|
|
LaserLinc Dual-Axis Micrometer Brochure
Download (PDF 510K)
 |
| TLAser2120 Micrometer Specifications |
| • |
Measurement range is .028" - 4.72" (.7mm - 120mm) |
| • |
Resolution is .000001" (.025µm) |
| • |
Two-second measurement repeatability is ±.00004" (±1µm) |
| • |
Positional error ±.0004" (±10µm) within center 4" (102mm) |
| • |
Measurement rates up to 8,000 (2,000 standard; 4,000 and 8,000 optional) measurements per second per axis |
| • |
Weight is 53 lbs (24 kg) |
| • |
Dimensions are 20.25"L x 3"W x 22.1"H |
| • |
Part aperture is 8" x 10" (without air purge) |
| • |
TLAser400 supports up to four TLAser2120 micrometers per card |
| • |
Laser Class II visible red laser diode wavelength is 675 nm |
 |
|