Versatility is an important feature of the LaserLinc single-axis TLAser122 micrometer. This model employs an advanced prism-based scanning technology. It is designed to be extremely repeatable, accurate, compact, and affordable. It is optimized for use with the TLAser400 interface card and LaserLinc's Total Vu software.
The TLAser122 is a great choice for multi-strand measurement of products such as enameled wire and fiber ribbon. The multi-strand option in Total Vu software offers 100% inspection of a virtually unlimited number of strands, using one or more micrometers.
It is also an excellent bench-top inspection systemvisit our BenchLinc system page for systems that combine the TLAser122 with an auto rotating zero chuck and specialized LaserLinc software.
The TLAser122 provides a PC-based means for achieving greater processing power, data storage, and network flexibility. You can process data at the full measurement rate of all the micrometers connected to your systemup to four TLAser400 cards per computer, for a total of 16 micrometers.
You can measure multiple strands simultaneously (as many as you want) with LaserLinc's TLAaser400 card and the laser micrometers of your choice, to assure precise and complete inspection on optical fiber, magnet wire, or monofilament production lines.
|
|
|
|
|
TLAserX22 micrometer brochure
Download (PDF 808K)
|
|
|
|
|
|
|
|
Measurement
Range
|
.0015˝ .85˝
(.035mm 22mm)
|
|
|
|
Maximum Measurement Size
|
.85˝
(22mm)
|
|
|
|
Measurements
Per Second
|
400
|
|
|
|
Resolution
|
.000001˝ (.025µm)
|
|
|
|
Repeatability*
|
|
|
Single Scan
|
±.0001˝ (±.2.5µm)
|
|
|
|
Two Second
|
±.000005˝ (±.125µm)
|
|
|
|
Positional Error
|
±.00245˝ (.06mm)
within center .79˝ (20.32mm)
|
|
|
|
Approx.
Dimensions
(H x W X D)
|
4˝ x 10˝ x 1.25˝
(102mm x 254mm x 32mm)
|
|
|
|
Approx.
Weight
|
2.6 lbs
(1.2kg)
|
|
|
|
Power requirements from PC
|
+12VDC 125mA, +5VDC 75mA,
5VDC 50mA
|
|
|
|
|
Run up to 16 TLAser122 micrometers per PC.
Laser Class II visible red laser diode wavelength is 675nm.
|
|
|
|
*Repeatability applies within the measurement range.
|
|